fxo ringing_inter_cycle
set port
port
fxo ringing_inter_pulse
5.10.8 set
port
port
fxo ringing_inter_cycle
The FXO port detects ringing for signifying an incoming call. A ring is a cycle of
ring-on and ring-off signals. This command is used to specify the time between
consecutive ring-on signals, that is, the duration of the ring-off signal, in
milliseconds. It is used to detect ringing.
set port port fxo ringing_inter_cycle milliseconds
Syntax description
milliseconds
Time in milliseconds, ranging
from 1 to 6000.
Default
4000
Related Command
set port
port
fxo ringing_db
set port
port
fxo ringing_inter_pulse
5.10.9 set
port
port
fxo ringing_inter_pulse
The FXO port detects ringing for signifying an incoming call. A ring is a cycle of
ring-on and ring-off signals. The ring-on signal is comprised of a sequence of pulses.
This command is used to specify the time between consecutive ring pulses in the
same ring-on signal in milliseconds (that is, one half the inverse of ring frequency).
For instance, if the ring frequency is 25 Hz, then the period of a ring-on signal is 40
ms, and the ringing_inter_pulse is 20 ms. It is used to detect ring-on.
set port port fxo ringing_inter_pulse milliseconds