![Solwise Elite ITG Extera Set-Up Instructions Download Page 75](http://html1.mh-extra.com/html/solwise/elite-itg/elite-itg_extera-set-up-instructions_1317166075.webp)
Solwise Elite VoIP Gateway User’s Guide
75
Syntax description
milliseconds
Time in milliseconds, ranging
from 0 to 65535.
Default
100
5.8.7 set
port
port
emd out_intg_check
This command is used to set the Integrity Check mode. If On, the delay signal
response is required from the PBX for outgoing calls. If Off, no Integrity Check is
performed.
set port port emd in_digit_ign
[on | off]
Syntax description
on
Perform Integrity
Check
off
No Integrity Check is
performed
Default
off
5.9 E&M Wink Start Signaling Configuration Commands
The E&M wink start signaling configuration commands are used to define
parameters specific to E&M wink start interface. These commands apply to E&M
Wink Start signaling protocol only.
5.9.1 set
port
port
emw in_wink_digit_ignore
This command is used to specify the period of time that will be ignored after
completing the wink and before digits will be accepted for incoming calls.
set port port
emw in_wink_digit_ignore
milliseconds
Syntax description
milliseconds
Time in milliseconds, ranging
from 0 to 65535.