5.6.11 set
port
port
em size_detect
This command is used to specify the period of time the M-lead needs to be off-hook
before an incoming call is declared.
set port port em size_detect milliseconds
Syntax description
milliseconds
Time in milliseconds, ranging
from 0 to 65535.
Default
150
5.7 E&M Immediate Start Signaling Configuration Commands
The E&M immediate start signaling configuration commands are used to define
parameters specific to E&M immediate start interface. These commands apply to
E&M Immediate Start signaling protocol only.
5.7.1 set
port
port
emi glare_report
This command is used to set a time period during which, if glare is detected, the
interface will stay off-hook and generate congestion tone.
set port port emi glare_report milliseconds
Syntax description
milliseconds
Time in milliseconds, ranging
from 0 to 65535.
Default
5000
5.7.2 set
port
port
emi wait_dsp_ready
This command is used to set a time period (in milliseconds) to wait for the DSP
software to be ready before digit collection can be enabled. If glare is detected
during this period, the interface will stay offhook and generate congestion tone.
set port port emi glare_report milliseconds
Syntax description
milliseconds
Time in milliseconds, ranging
from 0 to 65535