Solwise Elite VoIP Gateway User’s Guide
79
5.10.3 set
port
port
fxo caller_id
This command selects if Caller ID will be detected on the FXO port.
set port port fxo caller_id {on | off}
Syntax description
on
Enable Caller ID
detection
off
Disable Caller ID
detection
Default
on
Related Command
set port
port
enable_user_cid
5.10.4 set
port
port
fxo cpc_detect
The ITG incorporates loop current and battery reversal detectors on the FXO
interface. Upon detecting loss of loop current on a FXO port for a specific duration,
the ITG shuts down the port. This command is used to specify the expected duration
of the loss of loop current (CPC supervisory disconnect signal) in milliseconds. If
the loop current on a FXO port drops for a time period greater than this duration, it is
regarded as a supervisory disconnect and the ITG shuts down the port.
set port port fxo cpc_detect milliseconds
Syntax description
milliseconds
Time in milliseconds, ranging from 1 to
60000. –1 stands for no loop current and
battery reversal detection
Default
-1. Do not detect loop current loss and battery reversal.
Related Command
set port
port
fxo loop_det_db
5.10.5 set
port
port
fxo guard_out
After completing a call over a FXO port, there a short time interval the ITG does not
allow originating outgoing calls, however, incoming calls will be received. This