![Solwise Elite ITG Extera Set-Up Instructions Download Page 74](http://html1.mh-extra.com/html/solwise/elite-itg/elite-itg_extera-set-up-instructions_1317166074.webp)
Solwise Elite VoIP Gateway User’s Guide
74
Syntax description
milliseconds
Time in milliseconds, ranging
from 0 to 65535.
Default
30
5.8.4 set
port
port
emd out_delay_check
This command is used to set the period of time after going off-hook on the E-lead
before checking the M-lead for the delay signal response. If the response is not seen
at this time, the call setup process will continue immediately.
set port port emd out_delay_check milliseconds
Syntax description
milliseconds
Time in milliseconds, ranging
from 0 to 65535.
Default
170
5.8.5 set
port
port
emd out_delay_dur_max
This command is used to set the maximum duration of the delay signal response on
the M-lead for it to be detected on outgoing calls.
set port port emd out_delay_dur_max milliseconds
Syntax description
milliseconds
Time in milliseconds, ranging
from 0 to 65535.
Default
8000
5.8.6 set
port
port
emd out_delay_dur_min
This command is used to set the minimum duration of the delay signal response on
the M-lead for it to be detected on outgoing calls.
set port port emd out_delay_dur_min milliseconds