SOFAR 3.3K~12KTL-X
User manual
All rights reserved
©
Shenzhen SOFARSOLAR Co ., Ltd.
- 66 -
ID65
Unrecover
HwAcOCP
The grid
current
is
too h i g h , a n
d h a s c a u s e
unrecoverable
hardware fault
ID65-ID70 are internal faults of SOFAR inverter, turn OFF
the “DC switch”, wait for 5 minutes, then turn ON the “DC
switch”. Check whether the fault is rectified. If no, please
contact SOFAR technical support.
ID66
Unrecover
BusOVP
The bus
voltage is too
high, and has
cause
unrecoverable
fault
ID67
UnrecoverI
acRmsUnb
alance
The grid
current is
unbalance,and
has cause
unrecoverable
fault
ID68
UnrecoverI
pvUnbalan
ce
The input
current is
unbalance, and
has cause
unrecoverable
ID69
Unrecover
VbusUnbal
ance
The bus
voltage Is
unbalance, and
has cause
unrecoverable
ID70
Unrecover
OCPInstant
The grid
current is too
high, and has
cause
unrecoverable
fault
ID71
Unrecover
PvConfigS
etWrong
Incorrect input
mode
Check the input mode(parallel mode/ independent mode)
setting of SOFAR inverter according to Section
4.5 of this user manual.
ID71- ID73 Reserved Reserved
Reserved
ID74
UnrecoverI
PVInstant
The input
current
is
too h i g h , a n
d h a s h a p p
e n
ID74-ID77 are internal faults of SOFAR inverter, turn OFF
the “DC switch”, wait for 5 minutes, then turn ON the “DC
switch”. Check whether the fault is rectified. If no, please
contact SOFAR technical support.