![Sofar solar 3.3K- 5.5KTL-X User Manual Download Page 70](http://html.mh-extra.com/html/sofar-solar/3-3k-5-5ktl-x/3-3k-5-5ktl-x_user-manual_1311971070.webp)
SOFAR 3.3K~12KTL-X
User manual
All rights reserved
©
Shenzhen SOFARSOLAR Co ., Ltd.
- 65 -
ID51
Consistent
Fault_DCI
The DCI
sampling value
between the
master DSP
and slave DSP
is not
consistent
ID52
Consistent
Fault_GFC
I
The GFCI
sampling value
between the
master DSP
and slave DSP
is not
consistent
ID53
SpiCommL
ose
The spi
communicatio
n between the
master DSP
and slave DSP
is fault
ID54
SciCommL
ose
The Sci
communicatio
n between the
control board
communicatio
n board is fault
ID55
RelayTestF
ail
The relays
fault
ID56
PvIsoFault
The insulation
resistance is
too low
Check the insulation resistance between the PV array and
earth(ground), if a short circuit occurs, rectify the fault.
ID57
OverTemp
Fault_Inv
The inverter
temp is too
high
Ensure the installation position and installation method
meet the requirements of Section 3.4 of this user manual.
Check whether the ambient temperature of the installation
position exceeds the upper limit. If yes, improve
ventilation to decrease the temperature.
Check whether the ID90~ID92 fault (fan fault) exist, if
yes, please replace the corresponding fan.
ID58
OverTemp
Fault_Boos
t
The Boost
temp is too
high
ID59
OverTemp
Fault_Env
The
environment
temp is too
high
ID60- ID64 Reserved Reserved
Reserved