![Sofar solar 3.3K- 5.5KTL-X User Manual Download Page 56](http://html.mh-extra.com/html/sofar-solar/3-3k-5-5ktl-x/3-3k-5-5ktl-x_user-manual_1311971056.webp)
SOFAR 3.3K~12KTL-X
User manual
All rights reserved
©
Shenzhen SOFARSOLAR Co ., Ltd.
- 51 -
Press"OK"button to enter mainl setting interface.Enter" 20.Set ElecMeter"
by pressing" Up"button or"Down"button, press"OK" button and enter"Input
Password"Setting interface.
Press"Back"button to set passwords(default: 0001),increase or decrease
value though pressing"Up"button or"Down"button, press"OK"button to
next value setting."Error! Try again"will be displayed for wrong
passwords.Press"Back"button and rekey in the correct passwords."success"
will be displayed if setting successfully.
Setting P(f)
Users can view the relationship between current active power and
frequency
Users press “Back” button to enter “1.Enter setting” interface, Press OK
button to enter main setting interface. Enter “21. Setting P(f)” by pressing
“Up” button Or “Down” button, then press “OK” button and enter “Setting
P(f)”interface. Then press Confirm button to start to Set P(f). "Success"
will be shown on the screen after a successful P(f) setting.
Setting Q(v)
Users can view the relationship between the current reactive power and
voltage
Users press “Back” button to enter “1.Enter setting” interface, Press OK
button to enter main setting interface. Enter “22. Setting Q(v) by pressing
“Up” button Or “Down” button, then press “OK” button . Then press
Confirm button to start to set Q(v)."Success" will be shown on the screen
after a successful Q(v) setting.
Control 81.S1
Enable frequency protection
Users press “Back” button to enter “1.Enter setting” interface, Press OK
button to enter main setting interface. Enter “23.Control 81.S1 by pressing
“Up” button Or “Down” button, then press “OK” button. Then press
Confirm button to start Control 81.S1.
Autotest Fast
Step 1: During the normal operation of our SOLAR inverters, press
“back” button (the leftmost button) to enter the main menu