SOFAR 3.3K~12KTL-X
User manual
All rights reserved
©
Shenzhen SOFARSOLAR Co ., Ltd.
- 50 -
“OK”
****
Input 0001
0001
“OK”
Anti Reflux Control
Hard Anti Reflux Control
Anti Reflux Control
“OK”
Enable
“OK”
*.**KW
Input the allowable export
power
Disable
Hard Anti Reflux
Control
“OK”
Enable
“OK”
*.**KW
Input the allowable export
power
Disable
Press
“
Up
”
or
“
Down
”
to change the value of the first digit. Press
“
OK
”
to switch to second digit.
Press
“
Up
”
or
“
Down
”
to change the value of the second digit. After inputting all digit press
“
OK
”
to
confirm.
Note
:
When enabling the Hard Anti Reflux Control and Anti Reflux
Control at the same time, generation limit control will be enabled. note that
the allowable export power of soft limit should be smaller than that of the
hard limit. After the setting is successful, the off-grid time after the
communication failure of the meter is changed from 5S to 15-20S.
MPPT Scan
Shadow scanning, when the component is blocked or abnormal, causing
multiple powerj peaks, by enabling this function, the peak point of
maximum power can be tracked.
Users press "Back"button to enter"1.Enter Setting"interface,
Press"OK"button to enter main setting interface.Enter"19.MPPT Scan" by
pressing" Up"button or"Down"button, press"OK" ,button and enter"Input
Password"Setting interface.
Press"Back"button to set passwords(default: 0001),increase or decrease
value though pressing"Up"button or"Down"button,press"OK"button to next
value setting."Error! Try again"will be displayed for wrong
passwords.Press"Back"button and rekey in the correct passwords."success"
will be displayed if setting successfully.
Set ElecMeter
Enable or disable meter functions.
Users press "Back"button to enter"1.Enter Setting"interface,