![Sofar solar 3.3K- 5.5KTL-X User Manual Download Page 29](http://html.mh-extra.com/html/sofar-solar/3-3k-5-5ktl-x/3-3k-5-5ktl-x_user-manual_1311971029.webp)
SOFAR 3.3K~12KTL-X
User manual
All rights reserved
©
Shenzhen SOFARSOLAR Co ., Ltd.
- 24 -
shielded network cable using a wire stripper.
Step 2
Open SOFAR 3.3K~12KTL-X lower cover and insert the shielded
network cable into the cable screw nut, seals, screw nut.
Step 3
Connect the stripped network cable to corresponding pins on the
plug, as shown as follow.
Figure 4-8 RS485 Connecting Communications Cables(1)
No.
Color
Function
1
White and orange
RS485 B-,RS485differentialsignal-
2
Orange
RS485 A-,RS485differentia
3
White and green
RS485 A-,RS485differentia
4
Blue
RS485 A-,RS485differentia
5
White and blue
RS485 B-,RS485differentialsignal-
6
Green
RS485 B-,RS485differentialsignal-
7
White and brown
NC
8
Brown
NC
Figure 4-9 RS485 Connecting Communications Cables(2)
Step 4 Crystal plug with RJ45 crimping tool.
Step 5 Insert the plug into the RS485 port on the SOFAR 3.3K~12KTL-X.
Step 6 Insert sealing plug into housing.
Figure 4-10 RS485 Connecting Communications Cables(3)
Follow-up Procedure
To remove an RJ45 connector from SOFAR 3.3K~12KTL-X, remove the
cable screw nut, press the clip on the RJ45
connector, and then pull out the shielded RJ45 connector.