SOFAR 3.3K~12KTL-X
User manual
All rights reserved
©
Shenzhen SOFARSOLAR Co ., Ltd.
- 63 -
circuit breaker and AC wiring of the SOFAR inverter.
ID14
HwBoostO
CP
Ihe input
current
is
too h i g h , a n
d h a s h a p p
e n hardware
protection
Check whether the input current is higher than the
maximum input current of SOFAR inverters, then check
the input wiring, if both are correct, please contact SOFAR
technical support.
ID15
HwAcOCP
The grid
current
is
too h i g h , a n
d h a s h a p p
e n hardware
protection
ID15-ID24 are internal faults of SOFAR inverter, turn OFF
the “DC switch”, wait for 5 minutes, then turn ON the “DC
switch”. Check whether the fault is rectified. If no, please
contact SOFAR technical support.
ID16
AcRmsOC
P
The grid
current is too
high
ID17
HwADFaul
tIGrid
The grid
current
sampling error
ID18
HwADFaul
tDCI
The DCI
sampling error
ID19
HwADFaul
tVGrid
The grid
voltage
sampling error
ID20
GFCIDevic
eFault
The GFCI
sampling error
ID21
MChip_Fa
ult
The master
chip fault
ID22
HwAuxPo
werFault
The auxiliary
voltage error
ID23
BusVoltZe
roFault
The bus
voltage
sampling error
ID24
IacRmsUn
balance
The Output
current is not
balanced
ID25
BusUVP
The bus
voltage Is too
If the PV array configuration is correct (no ID5 fault), the
possible cause is that the solar irradiance is too low.