![SMC Networks Oaziss Aegis RB6741-Z Installation Manual Download Page 106](http://html.mh-extra.com/html/smc-networks/oaziss-aegis-rb6741-z/oaziss-aegis-rb6741-z_installation-manual_1300606106.webp)
Technician
Operations
106
RB6741-Z Touchscreen Security System Installation Manual
Force-Defaulting a Smoke Detector
To force-default a smoke detector:
1.
Twist the back cover of the smoke detector to remove it from the device.
2.
Remove the batteries.
3.
Use a screwdriver to release the securing tabs that
secure the front cover and remove it.
4.
Locate the tamper switch on the circuit board (the
switch is at a 90º angle to the casing plane).
5.
While pressing and holding the tamper switch, insert a single battery into the smoke
detector. The LED goes ON.
6.
After 1 second, release the tamper switch. The LED blinks green.
7.
Replace the front cover.
8.
Replace all the batteries to the smoke detector.
9.
Replace the back cover.