Technician
Operations
102
RB6741-Z Touchscreen Security System Installation Manual
The following information appears about the sensor and security zone:
Sensor serial number and type (Door/Window, smoke detector, and so on)
Sensor signal strength detected by the Touchscreen
Security zone details such as its Display Icon and its function (Entry/Exit, Perimeter,
and so on)
Resetting Sensors to Factory Default Settings
When a sensor is removed from its packaging for the first time, it is in factory default mode.
When you install the battery as described in the documentation, the sensor searches for a
Touchscreen with which it can pair.
To reset a sensor that has already been added to a Touchscreen and place it in Search
mode, delete it as described in its documentation. In the unlikely event you need to force-
default a sensor that is not paired to a nearby Touchscreen, see the following pages:
Door/window sensors
— page 102
Glass break detector
— page 104
Motion detector
— page 105
Smoke detector
— page 106
For
any
sensors not listed or for the latest information, refer to the documentation that
came with the sensor.
Force-Defaulting a Door/Window Sensor
To force-default a door/window sensor:
1.
Find the locking mechanism on the bottom of the SMCDW02-Z.
2.
Holding the SMCDW02-Z in one hand, carefully insert the tip of a screwdriver into the
locking mechanism.