![SMC Networks LEY Operation Manual Download Page 36](http://html1.mh-extra.com/html/smc-networks/ley/ley_operation-manual_1299663036.webp)
- 35 -
5. Wiring of cables / Common precautions
Warning
1. Adjusting, mounting or wiring change should never be done before shutting off the power
supply to the product.
Electrical shock, malfunction and damaged can result.
2. Never disassemble the cable. Use only specified cables.
3. Never connect or disconnect the cable or connector with power on.
Caution
1. Wire the connector securely. Do not apply any voltage to the terminals other than those
specified in the product manual.
2. Wire the connector securely.
Check for correct connector wiring and polarity.
3. Take appropriate measures against noise.
Noise in a signal line may cause malfunction. As a countermeasure, separate high voltage and low
voltage cables, and shorten wiring lengths, etc.
4. Do not route wires and cables together with power or high voltage cables.
The product can malfunction due to interference of noise and surge voltage from power and high
voltage cables to the signal line. Route the wires of the product separately from power or high voltage
cables.
5. Take care that actuator movement does not catch cables.
6.
Operate with cables secured. Avoid bending cables at sharp angles where they enter the product.
7. Avoid twisting, folding, rotating or applying an external force to the cable.
Risk of electric shock, wire break, contact failure and loss of control for the product can happen.
8. Fix the cable protruding from the product in place before using.
The motor and lock cables are not robotic type cables and can be damaged when moved. Therefore fix
the cables and the connectors (part “A” in figure below) when set up.
9. Select “Robotic type cables” in case of inflecting actuator-cable repeatedly. And do not put
cables into a flexible moving tube with a radius smaller than the specified value. (Min. 50mm).
Risk of electric shock, wire break, contact failure and loss of control for the product can happen if
“Standard cables” are used in case of inflecting the cables repeatedly.
10. Confirm proper wiring of the product.
Poor insulation (interference with other circuits, poor insulation between terminals and etc.) can apply
excessive voltage or current to the product causing damage.
11. The Speed / pushing force may vary, depending on the cable length, load and mounting
conditions etc..
If the cable length exceeds 5m, the speed / pushing force will be reduced 10% per 5m as the maximum.
(If cable length is 15m: 20% reduction as the maximum. )
[Transportation]
Caution
1. Do not carry or swing the product by
the motor or the cable