- 26 -
Example of step data entry (2)
〈
Pushing operation -
【
INP
】
output signal
,
【
AREA
】
output signal
〉
a
b
c
d
e
f
g
h
i
j
k
No.
Move M
Speed
Position
Accel
Decel
PushingF TriggerLV PushingSp
MovingF
Area1
Area2
In pos
mm/s
mm
mm/s^2
mm/s^2
%
%
mm/s
%
mm
mm
mm
0 ABS
100
80.00
3000
3000
80
40
30
100
70.00
100.00
25.00
・
Step data no.0 : Positioning operation. (It moves to End limit after it moves from 0mm to 80mm.)
Condition 1) The
【
AREA
】
output signal is not used.
30
0
ON
OFF
100
80
0
40
102
0
10
20
30
40
50
60
70
80
90
100
Stroke [mm]
g TriggerLV[%]
(【
INP
】
Output condition
)
【
INP
】
Output signal
PushingF[%]
f
Speed[mm/s]
b
Position[mm]
c
In pos[mm]
k
PushingSp[mm/s]
h
Condition 2) The
【
AREA
】
output signal is used.
*
The
【
AREA
】
output signal is a signal output when the rod traverses through a certain range (The step
data:
Area 2
from
Area 1
).
This feature is useful when an output to check the rod position at intermediate stroke is required.
【
INP
】
Output signal
30
0
Speed[mm/s]
ON
OFF
b
100
80
0
PushingF[%]
f
40
g TriggerLV[%]
102
Position[mm]
c
In pos[mm]
k
PushingSp[mm/s]
h
【
AREA
】
Output signal
ON
OFF
Area1[mm]
j
Area2[mm]
j
(【
INP
】
Output condition
)
0
10
20
30
40
50
60
70
80
90
100
Stroke [mm]
・
The
【
AREA
】
output signal is
turned on from Area 1:70[mm]
between Area 2:100[mm].
・
The
【
INP
】
output signal is
turned on when trigger LV :
40[%] is exceeded.
・
The
【
INP
】
output signal is
turned on when trigger LV :
40[%] is exceeded.
/
See 7.2