- 56 -
(4) Set the “Load Mass” value in the controller setting software according to the approximate
weight of jigs or work pieces mounted on the Card Motor.
If the “Load Mass” value in the controller setting software and the weight of the workload are different,
the product may vibrate or the positioning accuracy may be reduced.
(5) INP output signal (OUT0)
The INP signal will go high (ON) when the table has reached within the INP output range of the target
position both in positioning operation and pushing operation.
In pushing operation, if the table exceeds the target position and moves outside the INP output range,
the INP signal will go low (OFF) again.
Output range of the INP signal (OUT0).
Model
Output range (mm)
LAT3F-
∗
±
0.05
LAT3-
∗
±
0.3
6. 3 Installation
(1) Install the controller and its peripheral devices on fireproof material.
Direct installation on or near flammable material may cause fire.
(2) Do not install these products in a place subject to vibration and impact.
Damage and malfunction can result.
(3) Do not mount the controller and its peripheral devices on the same base together with a
large-sized electromagnetic contactor or no-fuse breaker that generate vibration. Mount them
on different base plates, or keep the controller and its peripheral devices away from such
sources of vibration.
Damage and malfunction can result.
(4) Install the controller and its peripheral devices on a flat surface.
If the mounting surface is not flat or uneven, excessive force may be applied to the housing and other
parts resulting in malfunction.
6. 4 Power supply
(1) Use a power supply with low noise between lines and between power and ground.
In cases where noise is high, use an isolation transformer.
(2) The power supplies for the controller and for the parallel I/O can be separate, and both power
supplies must not be of “inrush-current limited” type.
If the power supply is of “inrush-current limited” type, a voltage drop may occur during the
acceleration or deceleration of the actuator.
(3) Take appropriate measures to prevent surges from lightning. Ground the surge absorber for
lightning separately from the grounding of the controller and its peripheral devices.
Warning
Warning