![background image](http://html1.mh-extra.com/html/smc-networks/lat3-series/lat3-series_operation-manual_1299750010.webp)
- 9 -
(5) Settings completed (Download)
After the operating conditions have been set in section
(4) above, click the [Download to Controller] button
(L) to complete the settings.
Caution
Refer to the LATC4 series (controller) operation manual for details of the data setting
procedures and buttons.
The Card Motor Product Number set in the Controller Setting Software must correspond with
the connected Card Motor.
If they do not correspond, the Card Motor will operate at a position, speed and thrust different
from the settings leading to operation failure.
Set the approximate value of the work load mounted on the table in the Load Mass box in the
Step Data section and check the operation.
If the actual weight of the workpiece and jig mounted on the Card Motor is largely different from
the work load set in the Step Data, the Card Motor may vibrate or the repeatability performance
may be poor. Check the operating conditions before setting and using the Card Motor.