- 15 -
1. 4 Operation by PLC
The step data set in the controller can be selected and the Card Motor operated to the steps using the
digital I/O signals of a PLC.
Complete and download to the controller the “Basic Parameter Setup” and “Step Data Setup” settings
before operating the product using a PLC. Refer to section “1.2 Controller settings” (P.7) for details of the
setting procedure.
Turn off the Controller Setting Software after the settings have been downloaded to the controller. Then
turn off the controller once and turn it on again, or set it to “Monitor Mode” in the “Monitor/Test” tab of the
Controller Setting Software. Refer to section “1.4 (5) Monitor Mode” (P.19) for details of the “Monitor
Mode”.
(1) Wiring
Switch the power off from the controller, and disconnect the controller setting cable from the controller.
Connect the controller and the PLC with the I/O cable.
(2) I/O cable
A
B
A10
A1 (Red)
B10
B1 (Red)
C
View C
A10
B10
A1
B1
Controller
M4 screw.
Grounding cable with crimped terminal.
Shakeproof washer.
(to be prepared by the user)
24 VDC power supply
for the input / output
signals
(to be prepared by the
user)
Card Motor
Actuator cable
Power supply plug
(attached to the controller)
Power supply cable
(to be prepared by the user)
Counter plug
(attached to the controller)
I/O cable
PLC
(to be prepared by the user)
24 VDC power
supply for the
controller
(to be prepared by
the user)