No.JXC#-OMX0009-A
2.5 Start up procedure
Be sure to check the procedure below before use.
(1) Checking the contents of the package
After unpacking everything, check the description on the label to identify the controller and the number
of accessories. If any parts are missing or damaged, please contact your distributor.
*1) These items are included when ordered
using the part number for an actuator
set.
[Options]
● Teaching box
● Communication cable
for controller configuration
●
Actuator cable
●Communication plug
(2) Mounting the controller
Refer to section
3.4 Mounting
for instructions on how to mount the controller.
(3) Controller Setting
It is necessary to set the address and the communication speed by the rotary switch of controller.
Please refer to the
“4.1 Switch (STAION NO., B RATE)”
(4) PLC set up
Set the PLC parameter as a master station. Please refer to the
“4.3 PLC setting”
.
(5) Wiring and Connection
Prepare the electric actuator and the cable.
Connect the cables to the controller.
Refer to
5. External Connections
for the wiring of the connectors.
Controller
Power supply plug Communication plug
Teaching box
Actuator cable
Product name
Quantity
Controller
(JXCM1##-#)
1 pc.
Power supply plug
(JXC-CPW)
1 pc.
Communication plug
(LEC-CMJ-#)
*1
)
1 pc.
Communication cable
for controller configuration