- 113 -
No.JXC#-OMX0009-A
5
F to 0
Target
position
Address
(always 0)
5
F to 0
Acceleration
(Pushing force)
DATA(L)
6
F to 0
DATA(H)
6
F to 0
Deceleration
(Trigger LV)
Occupation
area
7
7 to 0
Alarm 1
DATA(L)
7
F to 0
Pushing
speed
F to 8
Alarm 2
*4) Set always OFF(0)
●Full numerical data instructions (4 Stations occupied) [Remote IO]
PLC memory
address
Signal name
PLC memory
address
Signal name
Rx
Ry
00
OUT0
00
IN0
01
OUT1
01
IN1
02
OUT2
02
IN2
03
OUT3
03
IN3
04
OUT4
04
IN4
05
OUT5
05
IN5
06
-
06
-
07
-
07
-
08
BUSY
08
HOLD
09
SVRE
09
SVON
0A
SETON
0A
DRIVE
0B
INP
0B
RESET
0C
AREA
0C
SETUP
0D
WAREA
0D
JOG(-)
0E
ESTOP
0E
JOG(+)
0F
ALARM
0F
FLGTH
10 to 6F
(No used)
10 to 6F
(No used)
7A to 70
CC-Link system
area
7F to 70
CC-Link system
area
7B
Remote station
READY
7F to 7C
CC-Link system
area