- 112 -
No.JXC#-OMX0009-A
●Half numerical data instructions (2 Stations occupied) [Remote IO]
PLC memory
address
Signal name
PLC memory
address
Signal name
Rx
Ry
00
OUT0
00
IN0
01
OUT1
01
IN1
02
OUT2
02
IN2
03
OUT3
03
IN3
04
OUT4
04
IN4
05
OUT5
05
IN5
06
-
06
-
07
-
07
-
08
BUSY
08
HOLD
09
SVRE
09
SVON
0A
SETON
0A
DRIVE
0B
INP
0B
RESET
0C
AREA
0C
SETUP
0D
WAREA
0D
JOG(-)
0E
ESTOP
0E
JOG(+)
0F
ALARM
0F
FLGTH
10 to 2F
(No used)
10 to 2F
(No used)
3A to 30
CC-Link system area
3F to 30
CC-Link system area
3B
Remote station READY
3F to 3C
CC-Link system area
●Half numerical data instructions (2 Stations occupied) [Remote register]
PLC
memory
address
RWr Data name
PLC
memory
address
RWw Data name
RWr
bit
Numerical data
instructions
operation
Data editing
RWw
bit
Numerical data
instructions
operation
Data editing
0
0
Return of Occupied number of
stations (L)
0
0
Setting read numerical data
1
Return of Occupied number of
stations (H)
1
Setting parameter rewriting
2
Sending
2
Reset flag
3
Sending completed
3
Restart flag
4
READY
4
Movement
MOD
Start flag
5
ALARM flag
5
Speed
(No used)
Set always OFF(0)
6
Initial
6
Position
7
Return of the read numerical
data
7
Acceleration
8
Return of parameter rewriting
8
Deceleration
9
(No used)
9
Pushing
force
A
A
Trigger LV
B
B
Pushing
speed
C
C
(No used)
Set always OFF(0)
D
Data editing error receiving
D
E
Parameter anomaly detection
E
F
The abnormal station detection
F
1
F to 0
Current position
1
0
Start flag
Sub Function
7 to 1 (No used)
*4)
F to 8
Movement
MOD
2
F to 0
2
F to 0
Speed
Address
3
F to 0 Current speed
Sub Function
3
F to 0
Target
position
Address
(Set always OFF(0))
4
F to 0 Current Force
Address
4
F to 0
DATA(H)