- 46 -
No.JXC
※
-OMV0005-A
11.3 Return to origin parameter
The "Return to origin parameter" is the setting data for the return to origin operation.
Details of Return to origin parameter
Activation: "■" = Effective as soon as it is recorded into the controller
"O" = Become effective after restarting the controller
"-" = The parameter cannot be changed (fixed value)
Description
Range
Explanation
Activation
Controller
setting
software
Teaching
box
IO-Link
ORIG
direction
ORIG
direction
ORIG
direction
1 to 2
Sets the direction of return to origin operation.
1. CW
2. CCW
○
ORIG
mode
ORIG
mode
ORIG
mode
1 to 2
The setting for the return to origin operation.
1. Pushing origin operation [Stop]
2. Limit switch origin [Sensor]
■
ORIG limit ORIG limit ORIG limit
(
1)
A pushing force level at which to set the origin. (Unit: %)
■
ORIG time ORIG time ORIG time Fixed value
This is the fixed value for this controller.
(
Do not change the setting)
-
ORIG
speed
ORIG
speed
ORIG
speed
(
1)
The allowable speed to move to origin.(Unit: mm/s)
■
ORIG
ACC/DEC
ORIG
ACC/DEC
ORIG
ACC/DEC
(
1)
The acceleration and deceleration during finding origin.
■
Creep
speed
Creep
speed
Creep
speed
Fixed value
This is the fixed value for this controller.
(
Do not change the setting)
-
ORIG
sensor
ORIG
sensor
ORIG
sensor
0 to 2
The setting for ORIG sensor.
0. The origin sensor is not effective. [Disable]
1. The origin sensor is N.O type. [N.O].
2. The origin sensor is N.C type. [N.C.]
■
Origin
SW Dir
Origin
SW DIR
ORIG SW
Dir
Fixed value
This is the fixed value for this controller.
(
Do not change the setting)
-
Undefined
parameter
No. 21
Undefine
No. 21
Undefined
parameter
21
Fixed value
This is the fixed value for this controller.
(
Do not change the setting)
-
1 The range varies depending on the actuator. Please refer to the manual of the actuator for more
details.
11.4 Drive parameter
The Drive parameter [Operation parameter] is data for setting jogging and inching movement.
This parameter can only be set using IO-Link communication.
Details of Drive parameter
Activation: "■" = Effective as soon as it is recorded into the controller
"O" = Become effective after restarting the controller
"-" = The parameter cannot be changed (fixed value)
Description
Range
Explanation
Activation
Only IO-Link
JOG speed
MAX speed
1)
The speed of Jogging / Inching is set by this setting. (Unit: mm/s
)
Jogging: JOG(+/-) , Inching: JOG(+/-) + FLGTH
■
Move distance
Actuator Stroke
(
1)
The distance of Inching is set by this setting. (Unit: mm
)
Inching: JOG(+/-) + FLGTH
■
1 The range varies depending on the actuator. Please refer to the manual of the actuator for more details.