- 38 -
No.JXC
※
-OMV0005-A
0x01
Bas
ic
Parameter1
Unit name
STR16
R/W Fixed value
-
-
Y
0x02
W-AREA1
INT32
R/W
Fixed value 0.01mm
-
Y
0x03
W-AREA2
INT32
R/W
Fixed value 0.01mm
-
Y
0x04
ORG correct
INT32
R/W
Fixed value
-
-
Y
0x05
Sensor type
UINT16
R/W
Fixed value
-
-
Y
0x0042
0x01
Basic
parameter2
Option set1
UINT16
R/W
Fixed value
-
-
Y
0x02
Undefined
parameter11
UINT16
R/W
Fixed value
-
-
Y
0x03
Undefined
parameter12
UINT16
R/W
Fixed value
-
-
Y
0x0043
0x01
Origin
parameter
ORIG direction
UINT8
R/W
Fixed value
-
○
Y
0x02
ORIG mode
UINT8
R/W
1,2
-
■
Y
0x03
ORIG limit
UINT8
R/W
5
%
■
Y
0x04
ORIG time
UINT8
R/W
Fixed value
0.1sec
-
Y
0x05
ORIG speed
UINT16
R/W
5
mm/s
■
Y
0x06
ORIG ACC/DEC
UINT16
R/W
5
mm/s
2
■
Y
0x07
Creep speed
UINT16
R/W
Fixed value
mm/s
-
Y
0x08
ORIG sensor
UINT8
R/W
0,1,2
-
■
Y
0x09
ORIG SW Dir
UINT16
R/W
Fixed value
-
-
Y
0x0045
0x01
Drive
parameter
JOG speed
UINT16
R/W
5
mm/s
■
Y
0x05
Move distance
UINT32
R/W
5
0.01mm
■
Y
1
UINT8: Unsigned Integer(1byte), UINT16: Unsigned Integer(2bytes), INT32: Signed Integer(4bytes), STR
: String(MAX
bytes)
2
R: Read
、
W: Write
3
"■" = Effective as soon as it is recorded into the controller, "○" = Become effective after restarting the controller
"-" = The parameter cannot be changed (fixed value)
4
Y: Parameter stored using data storage function, N: Parameter not stored using data storage function
Refer to
10.3 Data strorage (P.
for Data strage.
5
Different depending on the actuator type. Refer to the operation manual for the actuator.
(2-2) Current Alarm
Index
Sub
Index
Parameter name
Data type
1
Access
2
Description
Unit
Data
storage
4
0x0050
0x01
Alarm1
UINT8
R
0: No alarm.
Others: Alarm code
Refer to
17.2 Alarms and
countermeasures (P.
-
N
0x02
Alarm2
UINT8
R
0x03
Alarm3
UINT8
R
0x04
Alarm4
UINT8
R