- 45 -
No.JXC
※
-OMV0005-A
Para
protect
Para
protect
Para
protect
1 to 2
Sets the range in which parameter and step data can be
changed.
1. Basic par Step data (Basic par Return to
origin par Step data)
2. Basic parameter (Basic par Return to origin
parameter)
■
Enable
SW
Enable
SW
Enable
SW
1 to 2
This defines the status of the Enable switch of the teaching
box.
1. Enabled
2. Disabled
■
Unit
name
Unit
name
Unit
name
Fixed value
Indication of actuator type compatible with the controller.
(Do not change the setting)
-
W-AREA1 W-AREA1
W-AREA
1
Basic
parameter
"Stroke (-)" -
"Stroke (+)"
This is the setting to define the conditions where the
“W-AREA” signal will turn ON. (Unit: mm)
If the current position is within the range between the
W-AREA1 and W-
AREA2, “WAREA” will turn ON.
If W-AREA1 >W-AREA2, the "Parameter ALM" alarm will be
activated. However if W-AREA1= W-
AREA2 = 0, “WAREA”
will be OFF and no alarm will be generated.
■
W-AREA2 W-AREA2
W-AREA
2
Basic
parameter
"Stroke (-)" -
"Stroke (+)"
■
ORG
Correct
Link
Offset
ORG
Correct
Fixed value
This is the fixed value for this controller.
(
Do not change the setting)
-
Sensor
type
Sensor
type
Sensor
type
Fixed value
This is the fixed value for this controller.
(
Do not change the setting)
-
Option
set 1
Option 1
Option
set1
Fixed value
This is the fixed value for this controller.
(
Do not change the setting)
○
Undefined
parameter
11
Undefine
No. 11
Undefined
parameter
11
Fixed value
This is the fixed value for this controller.
(
Do not change the setting)
○
Undefined
parameter
12
Undefine
No. 12
Undefined
parameter
12
Fixed value
This is the fixed value for this controller.
(
Do not change the setting)
-
1 The range varies depending on the actuator. Please refer to the manual of the actuator for more
details.