In non-critical installations where the dust is evenly distributed and has time to spread without
reaching critical concentrations, we recommend a square side length of 20 m (65.6 ft).
•
In critical installations that are used in applications related to worker health or explosion
prevention, the grid should be narrower.
5.2.4
Orientation in wireless communication
If multiple devices are connected using a wireless RF connection, make sure that the devices are
oriented the same way with RF antennas pointing in the same direction. This helps prevent polarization
losses in the wireless communication.
5.3
Installing dust monitor
5.3.1
Safety precautions
WARNING!
Risk of burns due to hot components
When installing or removing equipment, the device or the installation surface can be
hot.
Wear appropriate heat-resistant gloves and follow all applicable local and plant-specific
safety codes before proceeding.
WARNING!
When installing the device, be aware of potential hazards related to the installation
location, for example when installing the device in tight spaces or near running
machinery. Make sure that there is room in the installation location for safe working.
NOTICE
Subjecting the device to any blows can damage it. Make sure that there is enough room
in the installation location to fit the entire device and any mounting hardware, and do
not subject the device to blows during installation or operation.
5.3.2
Installation
For mechanical installation, you need:
An electric drill and suitable drill bit for the surface you intend to install the device on
A tool for fastening screws
Marker
4× fasteners, max. M6
4× wall anchors