Press this button to activate / deactivate the Turbo function which enables the unit to reach the preset
temperature in the shortest time. In COOL mode, the unit will blow strong cooling air at super high fan speed. In
HEAT mode, the unit will blow strong heating air at super high fan speed.
15)
LIGHT:
Press LIGHT button to turn on the display's light and press this button again to turn off the display's light. If
the light is turned on,
is displayed. If the light is turned off,
disappears.
16)
X-FAN:
Pressing X-FAN button in COOL or DRY mode, the icon
is displayed and the indoor fan will continue
operation for 10 minutes in order to dry the indoor unit even though you have turned off the unit. After
energization, X-FAN OFF is defaulted. X-FAN is not available in AUTO, FAN or HEAT mode.
3.3.2 Guide for General Operation
1)
Combination of "
+
"and "
-
" buttons: About lock
Press "
+
" and "
-
" buttons simultaneously to lock or unlock the keypad. If the remote controller is locked,
is displayed. In this case, pressing any button,
blinks three times.
2)
Combination of "MODE " and "
-
" buttons :
About switch between Fahrenheit and centigrade At unit OFF, press "MODE" and "
-
" buttons
simultaneously to switch between
and
.
℃
℉
3)
Combination of " TEMP " and "CLOCK" buttons : About Energy-saving Function
Press “TEMP” and “CLOCK” simultaneously in COOL mode to start energy-saving function. Nixie tube on
the remote controller displays “SE”. Repeat the operation to quit the function.
4)
Combination of "TEMP " and "CLOCK" buttons: About 8
℃
Heating Function
Press “TEMP” and “CLOCK” simultaneously in HEAT mode to start 8
℃
Heating Function Nixie tube on
the remote controller displays “
” and a selected temperature of “8
℃
”. (46
℉
if Fahrenheit is adopted). Repeat
the operation to quit the function.
5)
About Back-lighting Function
The unit lights for 4s when energizing for the first time, and 3s for later press.
a. Single control: it is intended to control the running parameters of a designated indoor unit individually.
conditioning system.
enient control to the air
ce shielding to realize conv
further, it also can set the weekly timer and long-distan
unit, including on/off, running mode, fan speed etc, and also perform the single control and centralized control,
Through this central controller, it is available to view and control those running parameters of the indoor
.
3 outdoor units and 16 indoor units
controlling up to
This central controller is a kind of regional controller, which is designed for free match units, capable of
4.1.1 Function Introduction
General Introduction
4.1
Central Controller SCC-16
4
23
Summary of Contents for MS-E48AIN
Page 1: ...HIGH POWER MULTI SYSTEM SERVICE MANUAL EN MS E48AIN MS E56AIN Outdoor unit ...
Page 11: ...CONTROL 1 OPERATION FLOWCHART 6 ...
Page 13: ...1 2 Heating Operation 8 ...
Page 47: ... Outdoor unit higher than indoor unit DB DB DB DB 42 ...
Page 70: ...Malfunction display High Pressure Protection 2 1 65 ...
Page 87: ...PARTS GUIDE MS E48AIN MS E56AIN DB2 19SB DB3 19SB DB5 16AF HIGH POWER MULTI SYSTEM ...
Page 88: ...Exploded view of unitMS E48AIN ...
Page 91: ...Exploded view of unitMS E56AIN ...
Page 94: ......
Page 95: ......
Page 96: ......
Page 97: ......