The place should be well-ventilated, so the machine can absorb and discharge sufficient air.
Outdoor unit shall be installed close to the indoor unit, hence to minimize the length and bends of
cooling pipe.
Avoid place the outdoor unit under the windows or between the constructions, hence to prevent normal
operating noise from entering the room.
Do not install in the place where there is flammable or explosive gas exist or a place subject to severe
dust, salty fog and polluted air.
Installation at the following places might lead to the air conditioner malfunction. If it is unavoidable, please
contact the appointed service center.
A place which is full of machine oil;
A region with saline-sodic soil near the sea;
A place where the sulphide fog exists, such as the sulphur spring;
A place where the high frequency facilities exist, such as radio equipment, electric welder and medical
equipment;
An environment with special conditions.
3.7
Outline Dimension of the Outdoor Unit
3.8
Installation and Servicing Space
1)
When the place of the installation is exposed to strong wind
When strong winds of 5 m/sec or more exist in the place of the installation, the outlet of the unit cannot face
the wind. If the wind blows against the outdoor unit's air outlet, it will cause deterioration of the operational
capacity and maybe break the fan.
2)
In case of installing only one unit
In case obstacles exist around the unit, the required installation space is in the following figure. The unit of the
values is mm.
3)
In case of installing multiple units(2 units or more)
In case multiple rows of series installation, the required installation space is in the following figure. The unit
of the values is mm.
34
Summary of Contents for MS-E48AIN
Page 1: ...HIGH POWER MULTI SYSTEM SERVICE MANUAL EN MS E48AIN MS E56AIN Outdoor unit ...
Page 11: ...CONTROL 1 OPERATION FLOWCHART 6 ...
Page 13: ...1 2 Heating Operation 8 ...
Page 47: ... Outdoor unit higher than indoor unit DB DB DB DB 42 ...
Page 70: ...Malfunction display High Pressure Protection 2 1 65 ...
Page 87: ...PARTS GUIDE MS E48AIN MS E56AIN DB2 19SB DB3 19SB DB5 16AF HIGH POWER MULTI SYSTEM ...
Page 88: ...Exploded view of unitMS E48AIN ...
Page 91: ...Exploded view of unitMS E56AIN ...
Page 94: ......
Page 95: ......
Page 96: ......
Page 97: ......