Testing the peripheral equipment
139
851-164336 / D
10.7 Trawl system
Observe the following procedure to test the trawl system interface.
1
Access the
I/O Setup
menu.
→
A procedure for this is located on page 130.
2
Select
Sensors
in the
I/O Setup
menu, then
Trawl System
,
and finally
ITI
or
FS3300
.
- Select ITI or FS3300 depending on the system you have
installed on your vessel.
3
Observe the
Sensor Config
submenu appears at the bottom
of the menu field.
4
Check that the settings in the
Sensor Config
submenu
correspond to your requirements for the serial line.
5
Press
Close
to exit the
Sensor Config
menu.
6
Check the trawl readouts as follows:
a
Select the
Setup
menu.
b
Press the
Gear
button to access the
Gear
submenu at the
bottom of the menu field.
c
Select either of the
Bottom Trawl
or
Pelagic Trawl
settings.
d
Press the
Edit
button to access the
Trawl Configuration
submenu
e
Check that the different readouts in the submenu
corresponds to those from the connected trawl system.