Simrad SP70
96
851-164336 / D
Figure 33 Mains
connection to the
motor
230 Vac
380 / 440 Vac
1
Remove the hand crank from its storage position.
2
Set the motor overload switch
S301
to normal position by
pressing the black button marked ”1”.
3
Set the hoisting/lowering switch
S302
to
Lower
.
4
Check the training direction of the hoisting/lowering motor
by briefly pressing the hand crank safety switch
S303
.
5
If the transducer shaft was hoisted, perform the following
procedure:
a
Disconnect the ship’s 3-phase mains fuses
b
Change two of the connections to the terminals on the
motor overload switch
S301
.
c
Reinsert the 3-phase mains fuses in the ship’s fusebox.
6
Set the hoisting/lowering switch
S302
to
Stop
.
7
Put the the hand crank back to its storage position in the
Motor Control Unit.
8
Check if there is sufficient space under the keel to lower the
transducer.
9
Make sure that the flexible transducer cable is in such a
position that the transducer can be lowered without
stretching or hard-bending the cable.
Note
Watch this carefully during the next steps in this procedure!
10
Set the hoisting/lowering switch
S302
to the
Lower
position
to completely lower of the transducer.
Summary of Contents for Simrad SP70