![Silicon Laboratories Si4430 Manual Download Page 10](http://html1.mh-extra.com/html/silicon-laboratories/si4430/si4430_manual_1272042010.webp)
S i 4 4 3 0
10
Preliminary Rev. 0.4
Table 4. Transmitter AC Electrical Characteristics
1
Parameter
Symbol
Conditions
Min
Typ
Max
Units
TX Frequency
Range
1
F
SYNTH
900
—
960
MHz
FSK Modulation Data Rate
2
DR
FSK
1
—
128
kbps
OOK Modulation Data
Rate
2
DR
OOK
1.2
—
40
kbps
Modulation Deviation
1
Δ
f
Production tests maximum
limit of 320 kHz
±0.625
±320
kHz
Modulation Deviation
Resolution
Δ
f
RES
—
0.625
—
kHz
Output Power Range
1
P
TX
Power control by txpow[2:0] Register
Production test at txpow[2:0] = 111
Tested at 915 MHz
–8
—
+13
dBm
TX RF Output Steps
2
P
RF_OUT
controlled by txpow[2:0] Register
—
3
—
dB
TX RF Output Level
Variation vs. Voltage
2
P
RF_V
Measured from VDD=3.6 V to
VDD=1.8 V
—
2
—
dB
TX RF Output Level
2
Variation vs. Temperature
P
RF_TEMP
–40 to +85
C
—
2
—
dB
TX RF Output Level
Variation vs. Frequency
2
P
RF_FREQ
Measured across any one
frequency band
—
1
—
dB
Transmit Modulation
Filtering
2
B*T
Gaussian Filtering Bandwith Time
Product
—
0.5
—
Spurious Emissions
2
P
OB-TX1
P
OUT
= 11 dBm,
Frequencies <1 GHz
—
—
–54
dBm
P
OB-TX2
1–12.75 GHz, excluding harmonics
—
—
–54
dBm
Harmonics
2
P
2HARM
Using Reference Design TX Matching
Network and Filter with Max Output Power
(+13 dBm). Harmonics reduce linearly with out-
put power
—
—
–42
dBm
P
3HARM
—
—
–42
dBm
Notes:
1.
All specification guaranteed by production test unless otherwise noted.
2.
Guaranteed by qualification.