SWH(time-server)# and press enter.
<time_zone>: 1~146
day-saving <enable | disable>
To enable or disable the daylight saving time
function.
offset <hour>
To offset 1 hour or 2 hours for daylight saving
function.
exit
Quit the current mode and return to Enable
mode.
show
Show currently-configured time server
settings.
2.5.9 Upgrade command mode
Enter the upgrade command in Enable mode. Then, the upgrade mode shows as follows:
SWH# upgrade
SWH(upgrade)#
Command
Purpose & Description
Usage
=================== =========================== =============================
firmware Upgrade Firmware firmware
config Upgrade Configuration config
exit Exit from current mode exit
SWH(upgrade)#
Prompt
Command & Parameter
Description
firmware <ftp|tftp> <serverip>
[username] [password]
<filelocation>
To upgrade Firmware via FTP or TFTP.
<serverip>: Enter the IP address of the FTP
or TFTP server.
[username]: Enter the username for
Firmware upgrade via FTP.
[password]: Enter the password for
Firmware upgrade via FTP.
<filelocation>: Enter the file location within
the FTP or TFTP server.
Please refer to
APPENDIX C
for Firmware
upgrade via TFTP server.
For example:
SWH(upgrade)# firmware tftp 192.168.0.15
SWH2126_FW_1.01.00_20100105.bin
config <ftp|tftp> <serverip>
[username] [password]
<filelocation>
To upgrade a configuration file via FTP or
TFTP.
<serverip>: Enter the IP address of the FTP
or TFTP server.
[username]: Enter the username for
configuration file upgrade via FTP.
[password]: Enter the password for
configuration file upgrade via FTP.
<filelocation>: Enter the file location within
the FTP or TFTP server.
SWH(upgrade)#