Step 2. Login the Managed Switch
Access the Managed Switch via “RS-232” console with the following settings:
Default IP address of the Managed Switch:
192.168.0.1
Default Console Rate:
9600, N, 8, 1
Username:
admin
Password:
By default, no password is required.
(Press Enter)
NOTE: If Telnet is used, please check your IP address as well. It must belong to
192.168.0.0/24 network domain, for example, 192.168.0.15.
Step 3. Setup the Upgrade Configuration
Use the following commands to update Firmware.
Username: admin
Password:
SWH> enable
Password:
SWH# upgrade
SWH(upgrade)# firmware tftp 192.168.0.15 500-7624FE2GC_FW_1.02.1A_101203.bin
In the preceding example, “192.168.0.15” is the IP address for TFTP server. “500-
7624FE2GC_FW_1.02.1A_101203.bin” is the file name that will be uploaded to the Flash of
the Managed Switch. When Firmware upgrading is complete, the Managed Switch will be
rebooted to run the new Firmware. Please do not turn off power during reboot process.