56
User Manual
⚫
If the
Normal
marker is selected, the start frequency will be set to the frequency of the current
marker.
⚫
If the
Delta
or
Delta Pair
marker is selected, the start frequency will be set to the frequency of
the Delta Marker.
⚫
The function is invalid in Zero span.
Command format
:CALCulate:MARKer[1]|2|3|4|5|6|7|8[:SET]:START
Instructions
Sets/gets the value of the marker X axis to the starting frequency, valid when the
marker is on
Example
:CALCulate:MARKer1:START
3.7.10.4
M -> Stop Freq
Set the stop frequency of the analyzer to the frequency of the current marker.
⚫
If the
Normal
marker is selected, the stop frequency will be set to the frequency of the current
marker.
⚫
If the
Delta
or
Delta Pair
marker is selected, the stop frequency will be set to the frequency of
the Delta Marker.
⚫
The function is invalid in Zero span.
Command format
:CALCulate:MARKer[1]|2|3|4|5|6|7|8[:SET]:STOP
Instructions
Sets/gets the value of the marker X axis to terminate frequency
If the corresponding marker is not open, sending this command will automatically
open the marker at the end frequency.
Example
:CALCulate:MARKer1:STOP
3.7.10.5
M ->Ref Level
Set the reference level of the analyzer to the amplitude of the current marker.
⚫
If the
Normal
marker is selected, the reference level will be set to the amplitude of the current
marker.
⚫
If the
Delta
or
Delta Pair
marker is selected, the reference level will be set to the amplitude of
the Delta Marker.
Command format
:CALCulate:MARKer[1]|2|3|4|5|6|7|8[:SET]:RLEVel
Instructions
Sets/gets the value of the marker Y-axis as a reference level
If the marker is not open, this command automatically turns the marker on the