User Manual 153
5.1.5
BERT
Bit error rate test function, that is, the analyzer uses the measurement result of the current
demodulation analysis and the preset reference signal to compare by bit to obtain the bit error
rate.
Reference signals that can be preset in the editing interface and can be saved to a user profile
(.sta file) and loaded.
Command format
[:SENSe]:DDEMod:SEGMent:BER:STATe
[:SENSe]:DDEMod:SEGMent:BER:STATe?
Instructions
Setting the BERT switch
Querying the BERT switch
Parameter type
Boolean
Parameter Range
OFF|ON|0|1
Return
Boolean
Example
:DDEMod:SEGMent:BER:STATe ON