3.3
Device identification
Each part of the FC330 Coriolis flowmeter has 3 nameplate types which show the following
information:
● product identification
● product specifications
● certificates and approvals
Note
Identification
Identify your device by comparing your ordering data with the information on the product and
specification nameplates.
Transmitter identification nameplate example
6\VWHPRUGHUQR0(/$*&=
$%()&/
7UDQVPRUGHUQR0(/$1&=
$%()&/
3RZHUVXSSO\9$&WR+]9$RU9'&:
0DWHULDO9HUVLRQ$OXPLQLXP5HPRWH
&RQGXLW&DEOHHQWULHV[0[0[
6HULDOQR1.;;;;;;;
6\VWHPUHYLVLRQV
):+:
<HDURIPDQXIDFWXUH
(QFORVXUH,37\SH;
7DPEr&r)WRr&r)
6,75$16)&7
SIEMENS
6LHPHQV$*'(.DUOVUXKH
0DGHLQ*HUPDQ\DVVHPEOHGLQ)UDQFH
①
SITRANS FCT030
1)
Product name
②
Serial no.
Serial number
③
System revisions
System revision numbers firmware (FW) and hardware (HW)
④
Year of manufacture
Manufacturing year
⑤
Enclosure
Degree of protection
⑥
Tamb.
Range of ambient temperature
⑦
Manufacturer
Manufacturer name and location
⑧
Country
Manufacturing country
⑨
Conduit / Cable entries Type of conduit / cable entries
⑩
Material / Version
Transmitter housing material and version (compact/remote)
⑪
Power supply
Power supply
⑫
Transm. order no.
Device-specific transmitter order number
⑬
System order no.
Device-specific system order number (transmitter and sensor)
1)
With compact versions, the transmitter and sensor product identifications are both given as 'SITRANS
FC330'.
With remote versions, the transmitter is identified as 'SITRANS FCT030' and the sensor as 'SITRANS
FCS300'.
Description
3.3 Device identification
SITRANS FC330
Operating Instructions, 01/2019, A5E44030648-AB