Network and system integration
4.2 System configuration via PROFINET/PROFIBUS with CM
SIMATIC MV500
54
Operating Instructions, 06/2018, C79000-G8976-C494-01
4.2
System configuration via PROFINET/PROFIBUS with CM
①
Optical sensor or light barrier (for trigger signal)
②
Object with code
Figure 4-1
Example: System configuration via PROFINET IO/PROFIBUS DP-V1 with
communication module
System characteristics
●
The PROFINET/PROFIBUS connection is made via the CM interface of the optical reader
and a communication module.
●
PROFINET IO/PROFIBUS DP-V1 is connected to an S7 controller.
●
The optical reader is controlled via PROFINET IO/PROFIBUS DP-V1 using the Ident
profile block by the S7 controller.
●
The result is output via PROFINET IO/PROFIBUS DP-V1 to the S7 controller.
●
The optical reader is supplied with power via the communication module.
●
The optical reader is triggered either via digital I/O, S7 controller or via the built-in auto-
trigger function.
●
A PC/PG is connected via the Ethernet interface to allow adjustment of the device.