6AW5451-6XX01-1K
ES 030-K Manual
3 - 28
Subject to change without prior notice
RD: 08.2000
(4)J31069-D0136-U001-A0-7618
FY 16/17 Assignment
Initiation:
Set by the user. The system will reset the flag and set the acknowledge flag.
Acknowledge:
Set by the system after the task has been performed. Reset by the user and by the system upon
new initiation.
Error:
Set by the system. Exact description of errors is in DB 1 DW 54/56 (see also chapter 3.2.1.9 and
3.2.1.12). When an error occurs, the acknowledgement bit is set at the same time.
RESET command:
Set by the user. Reset by the system after execution. A command being executed will be cancelled
by the error message
“
RESET executed". The flags 16.3(17.3) and 16.0(17.0) must be
set simultaneously for the RESET command. The RESET indication will always be
acknowledged by acknowledgement flag 16.1 (17.1). The length of the user data in BEDB is over
written with
“
0".
NEXT command:
NEXT terminates the processing of an MDS (current MDS is still in the field or has already left the
field), which may consist of several commands. The next/following command will only be
processed with the next/new MDS. (System command; no dialogue is carried out with the MDS).
ECC command:
Set by the user. When flag 16.5 (17.5) is set to
“
1", processing will be carried out with ECC (Error
Correction Code); when set to
“
0", without ECC.
DIR has been read: Will be set when the directory has been read by the MDS.
ANW-bit:
Set by the system. Flag 16.7 (17.7) indicates whether there is a data memory (MDS) in the field or
not.
ECC operation
0 = OFF
(MOBY-I/L only)
1 = ON
Directory has been read from MDS
ANW bit:
1 = MDS in the field
Task initiation also on RESET and NEXT
Acknowledge
Error
RESET command
Bit 7 6 5 4 3 2 1 0
NEXT command
Connection 2
The structure of the MOBY-I connection 2 is analogous to the structure of connection 1. DW 53, 54, 80, 81, 82, and 83 are simply
replaced by DW 56, 84, 85,86, and 87; FY 16 is replaced by FY 17.