6AW5451-6XX01-1K
ES 030-K Manual
Subject to change without prior notice
3 - 33
RD: 08.2000
(4)J31069-D0136-U001-A0-7618
Structure of the Procedure for Serial Interfaces:
STX
Data
ETX
DB1 parameterization
DB xx
DB xx DW yy
Length
DW aa
DW bb
DW yy
Procedures
LAUF:
Free
STX
Data
Free
ETX
Extended LAUF procedure:
Free
XX
3964R:
STX
DLE
DLE
ETX BCC
DLE
PREMID:
STX
Check ETX
: The data can contain structures freely defined
by the user (e.g., definitions of addresses,
commands, and lengths, etc.). They are stored
by the user in the data block (DB xx, DW yy).
All other control bytes are provided by the
respective procedure. They do not have to be
taken into account during the programming by
the user.
Pointer scheme to the user data
DW aa, DW bb:
Different values of data for transmitting
and receiving, or for different
procedures.
Data
Data
Data
Data
3.4.5.3 Example Program
FB 1: SERIAL
:AN F 1.0
Voltage return
:JC=ANF
:A F 1.0
:R F 1.1
System start
:R F 1.0
Voltage return
:S F 12.1
Acknowledge for receiving flag
:R F 12.0
:S F 13.1
Acknowledge transmitting flag
:R F 13.0
:L KY 001,100
Display
:T DW 9
:L KY 000,040
:T DW 10
:S F 11.0
Display
ANF :
:A F 12.2
Receiving error
:BEB
:A F 12.1
:S F 12.0
Start reception
:R F 12.1
:S F 11.0
:
:A F 13.2
Transmitting error
:BEB
:A-START Auxiliary
flag
:A F 13.1
:S F 13.0
Start transmitting
:R F 13.1
:
:BE
DB 1
:
0:
KH = 0000
.
.
.
41: KH
=
1C02
42:
KY = 001,100 Pointer to receiving buffer
43: KY
=
000,040
44: KY
=
000,000
45:
KY = 001,150 Pointer to transmitting buffer
46: KY
=
000,040
.
.
.
100: KS
=
’XXXXXXXXXXXXXXXXXXXX’
101: C
=
’XXXXXXXXXXXXXXXXXXXX’
102: KH
=
0000
.
.
.
150: KS
=
’THIS IS A TEST ’
160: C
=
’OF THE SER. INTRFACE’
171: KH
=
0000
Summary of Contents for MOBY ES030-K