6AW5451-6XX01-1K
ES 030-K Manual
Subject to change without prior notice
3 - 9
RD: 08.2000
(4)J31069-D0136-U001-A0-7618
3.2.1.17 Error Codes
Channel 1:
DW 82/83
Channel 2:
DW 86/87
A0 06
Unknown command, the command designation KK is not valid.
A0 11
DBN not 1 on first command block; subsequent block has incorrect KK or DBN.
A0 15
Check byte error on reception from S5.
A0 16
Command from another sender is being processed.
PROTOCOL
ERRORS
SLG
ERRORS
MDS
ERRORS
JOB-
RELATED
ERRORS
DIRECTORY-
RELATED
ERRORS
FILE-
RELATED
ERRORS
B0 01
Error in connection to SLG (red LED blinks 3 x).
B0 02
1. Command on EAKO = 1; but no MDS present (timeout).
2. New MDS in field; no NEXT command, but command has been started (EAKO 0)
3. New MDS has left station without NEXT (EAKO 0).
C0 02
Error in the RAM of the MDS (red LED blinks 4 x).
C0 06
Presence error (red LED blinks 2 x).
C0 07
Parameterization error on TRACE or FORMAT/command cannot be interpreted (red LED blinks 5 x).
C0 08
Too many SYNCH attempts (red LED blinks 6 x).
C0 09
Too many transmission errors (red LED blinks 7 x).
C0 10
CRC transmission error (red LED blinks 8 x).
C0 11
FORMAT, CRC error on reception (red LED blinks 9 x).
C0 12
FORMAT, MDS cannot be initialized (red LED blinks 10 x).
C0 13
FORMAT, timeout (red LED blinks 11 x).
C0 14
FORMAT, not initialized (red LED blinks 12 x).
C0 15
CMD addressing error (red LED blinks 13 x).
C0 16
ECC error (red LED blinks 14 x).
C0 17
General driver error (red LED blinks 15 x).
D0 01
Only RESET command permitted (red LED blinks 1 x).
D0 05
Invalid parameter on FORMAT, CREATE, WRITE, UPDATE, ATTRIB, QUEUE-WRITE, or COVER.
D0 07
1. Incorrect data on LOAD command or LOAD command parameterized incorrectly.
2. MOVE command cannot be executed because checksum does not correspond to DIR + FAT.
D0 09
RESET command parameter incorrect.
D0 14
CREATE and WRITE: The user data area on the MDS is fully occupied.
D0 15
Only FORMAT command possible; MDS has not been identified.
D0 18
Start address in command is outside data area (start address > file length).
D0 22
Directory and/or FAT changing access to MDS protected by COVER is not permitted.
D0
23
COVER: MDS name incorrect.
E0 01
Wrong MDS type or not consistent with active operational mode (ECC).
E0 02
CREATE command: no directory entry available.
E0 03
CREATE command: File already exists in directory.
E0 05
1. FAT block sequence error has been detected during READ or WRITE, FAT defective.
2. Incorrect address specified on TRACE command.
F0 01
Addressed file does not exist.
F0 05
WRITE/UPDATE/DELETE command on file protected with applicable attribute.
PARAMETERI-
ZATION
ERRORS
H0 04
Command designation
“
KK" not permitted.
H1 07
DATDB not present in ES 030.
H1 12
“
KK" of command and acknowledge do not correspond.
H1 15
DATDB/DATDW parameters incorrect
H1 19
DATDB too short (preset length of command shorter than actually acknowledged).
QUEUE
parameter
assignment
Kx xx
1. xxx = Number of the file entry which is wrong
2. QUEUE-WRITE command is parameterized incorrectly.
3. The file to be created already exists.
3.2.1.18 DW 88 to DW 96 for PROFIBUSDP
DL 88
The user must enter the PROFIBUS address of the ES 030K here (value range: 3 to 124).
DR 88
The operating system of the ES 030K enters the firmware version of the PROFIBUSDP module here.
DW 89
Length of the data to be sent or the data received
DW 95
The user can enter any identifiers here. When sending a diagnosis, these
DW 96
bytes are sent to the bus master as
“
external diagnostics".
}
Summary of Contents for MOBY ES030-K
Page 1: ...s MOBY ES 030 K Acquisition Station Manual Release 08 2000 ...
Page 2: ......
Page 99: ......