3.2.1.10 DR 54, 56 Error Messages from the MOBY-L Module
Code
Description
Cause
No error
Presence error; no MDS present
Error in the connection to the SLG
Command from optional board cannot be interpreted
Wrong data on read-after-write
Wrong MDS type; field error (e.g. due to other SLG)
CRC transmit error
Incorrect write acknowledge from MDS
No read data, no write acknowledge
Field error due to radiated interference
CMD: address error
ECC operation: Incorrect data from MDS
CMD: previous command still active
MDS type has been parameterized incorrectly
CMD: not enough RAM on optional board
CMD: wrong
“
AB" byte; wrong data byte at RESET
00
02
03
05
06
07
08
09
0A
0C
0D
0E
19
1A
1D
1E
User program
Hardware: Channel module, cable
User program
SLG environment, hardware: SLG, MDS
SLG environment, hardware: SLG
SLG environment, test connector on option
SLG environment
MDS
SLG environment
User program
MDS, user
User program
User program
User program
User program
3.2.1.11 DR 54, 56 General MOBY Errors
Bit 7 6 5 4 3 2 1 0
Transmission interference (see module display)
Module defective
Cancelled due to RESET
Parameterization error
Transmission error to module
Battery monitor has been triggered (valid only for MDS types with RAM)
ECC correction has been performed (MOBY-I; MOBY-L)
Battery 2 (valid only for MDS 507 / 407E; MOBY-I)
3.2.1.12 DR 54, 56 Error Messages from the MOBY-I Module with File Handler
Bit 7 6 5 4 3 2 1 0
Transmission interference (see module display)
Module defective
Cancelled due to RESET
Parameterization error = error messages Hxxx (xxx = error number)
(see also DW 82/83 or DW 86/87)
Transmission error to module
3.2.1.13 DL 67, DR 67 MOBY Firmware Status
The same code is valid for both channels:
00
= no MOBY
01 ... 7F = MOBY-I without file handler or MOBY-L
80 ... FE = MOBY-I with file handler
FF
= always MOBY-M