6AW5451-6XX01-1K
ES 030-K Manual
Subject to change without prior notice
9 - 7
RD: 08.2000
(4)J31069-D0136-U001-A0-7618
9.7
Cabling
The technical description of the ES 030 and the description of the PG/PC interface must be observed when fabricating the cable.
25 pin
D-Sub,
male
25 pin
D-Sub,
female
7
COM1/V.24
Shield
Connect shield to
connector casing
Level converter
RS422<->V.24
is not required in
the special
version Z03
ES 030 25 pin
female pin
assignment
Signal Cable
LIYCY 5*0,14
PG/PC
25 pin male
pin assignment
2
TxD
wth
3
3
RxD
brn
2
jumper 4,5
7
GND
grn
7
jumper 6,8,20
casing
shield
casing
Cable length 3m
3
Adapter
PC / PG
ES 030
5
2
15
2
3
7
2
3
7
4
5
6
8
20