6AW5451-6XX01-1K
ES 030-K Manual
3 - 22
Subject to change without prior notice
RD: 08.2000
(4)J31069-D0136-U001-A0-7618
QUEUE-WRITE
Length of the data to be transferred in bytes
(sum of all file entries in bytes)
Pointer to user data that are to be transferred to the ES 030K.
The data are located in the DATDB beginning with
“
address"
DATDW.
KK =
“
Q" and KI =
“
I" (ASCII character)
File name: File name (as up to now)
Attribute: Attribute for this file. The attribute will not be set until
the data have been written.
Reserved: 1 byte is reserved.
Skip:
The Skip indicates how many bytes are skipped
between the end of an entry and before the next
file entry begins.
Example:
Skip = 0, (i.e., the file name of the next file entry)
immediately follows the data of the previous entry.
Length:
Length in bytes of the data to be written for the
indicated file. The data are located beginning after
the parameter
“
skip".
Data:
The data to be written. They may also be a fill pattern.
The amount of data in bytes must agree with the pa
rameter
“
length".
'Q'
'I'
xx
xx
xx
Option
xx
xx
xx
BEDB
DW n+1
DW n+2
DW n+3
DW n+4
DW n+5
DATDB
DATDW
DW n
As a result of the started command, the user will receive the set
“acknowledgement
bit". The user data area of
the user (DATDB) will not be changed.
This information has no meaning for this command.
xx: any characters
DLNG
DW n+6
'F'
'I'
'0'
'0'
DATDW:
Representation of the Data in the DATDB:
'L'
'E'
'0'
'1'
attribute
length (H)
length (I)
length (L)
reserved
skip
data
data
data
data
'F'
'I'
attribute
length (H)
length (I)
length (L)
reserved
skip
data
data
data
data
data
xx
'F'
'I'
'0'
'0'
'L'
'E'
'0'
'3'
Data entry 1
Data entry 2
etc.
The following applies if the data memory is already formatted
and contains an existing file structure:
Option=0000H: The file structure will be overwritten or
erased by QUEUE-WRITE.
Option=0001H: The file structure will be appended to the
existing file structure. A check if the file to be
created already exists will be carried out at
this time.
*)
'0'
'0'
'L'
'E'
'0'
'2'
Data entry 3
see*)