3.2.1.7 DR 54, DR 56 Error Messages from the MOBY-M Module
Code
Description
Cause
No error
Unknown command for the module
Error in data carrier type; unknown data carrier type or write
command on ROM
Error in the designated data carrier addresses
Error in the connection to LBS, wrong DAT type in field of LBS
or mutual interference of two LBSs
Loss of data on data carrier
A 64 byte DAT was addressed as 2 K DAT
A write command was cancelled by a RESET
Same as 58; but probably defective byte on DAT causes F 48
when reading this byte
00
08
10
18
40
48
50
58
60
User program
User program
User program
Cable, user program
Positioning
Battery empty, hardware (DAT defective)
User program
User program
User program
3.2.1.8 DR 54, DR 56 Error Messages from the MOBY-I Module without File Handler
Code
Description
Cause
No error
Optional board has not yet communicated with ES 030
Presence error; no MDS present
Error in the connection to the SLG
Error in RAM of MDS (not initialised)
Command from optional board cannot be interpreted
Too many SYNCH attempts; infected environment
Too many transmit errors
CRC transmit error
INIT: CRC error on receiving final acknowledge
INIT: MDS cannot be initialised
INIT: Timeout while waiting for acknowledge
INIT: MDS could not be initialised
CMD: address error
ECC operation: Incorrect data from MDS
CMD: previous command still active
MDS type has been parameterized incorrectly
CMD: not enough RAM on optional board
CMD: wrong
“
AB" byte; wrong data byte at RESET
00
01
02
03
04
05
06
07
08
09
0A
0B
0C
0D
0E
19
1A
1D
1E
User program
User program
Hardware: Channel module, cable
MDS: User program
User program
SLG environment, hardware: SLG, MDS
SLG environment, hardware: SLG
SLG environment, test connector on option
SLG environment
MDS
MDS, SLG environment
MDS
User program
MDS, user
User program
User program
User program
User program
3.2.1.9 DR 54, DR 56 Error Messages from MOBY-I Module with File Handler
Bit 7 6 5 4 3 2 1 0
Battery 2
MDS from field
The file which has been read has the length
“
0".
Battery 1
ECC has been corrected
Summary of Contents for MOBY ES030-K