Mounting Assembly Installation
1. Attach the Mounting Assembly to the clarifier handrail by hanging the upper and lower rail brackets
from the upper and lower rails.
2. The upper rail bracket is fixed. Check that the bolts are securely fastened.
3. Slide the lower rail bracket in position so that it rests on the lower rail. Tighten the slip bolts to
secure the bracket.
4. Insert the four larger u-bolts through the upper and lower brackets, clamping the brackets to the
rails and fasten with the supplied washers and nuts.
2.
slip bolts
3.
4.
4.
1.
1.