74
Hardware Description CNC 0610510/12
CNC 61.00
10.1.4
X13/X14 - Two Passive Transducers
This option provides two passive transducer inputs which are independent of each
other (measuring bridges for measuring torques/forces). The option module provides
the supply voltage for the measuring bridge (± 5 volts, max. 400 mA for both trans-
ducers) and an integrated measurement amplifier. Using the externally accessible
switches the sensitivity of the integrated measurement amplifier can be adjusted.
The corresponding signals are digitized by a 12 bits AD converter.
X13 - Transducer 1/2 passive
X
9-pole female Submin D connector
X14 - Transducer 2 passive
X
9-pole female Submin D connector
Pin
I/O
Function
1
I
Transducer input 1
2
I
Transducer input 2-
3
Supply voltage of +5 V for transducer
4
5
6
I
Transducer input 1+
7
I
Transducer input 2+
8
Supply voltage of -5 V for transducer
9
GND
Pin
I/O
Function
1
I
Transducer input 2-
2
3
Supply voltage of +5 V for transducer
4
5
6
I
Transducer input 2+
7
8
Supply voltage of -5 V for transducer
9
GND
1
5
6
9
1
5
6
9
Summary of Contents for CNC 0610510
Page 5: ... Content CNC 61 Hardware Description CNC 0610510 12 5 13 Appendix Revisions 101 ...
Page 6: ...Content 6 Hardware Description CNC 0610510 12 CNC 61 ...
Page 8: ...Symbols 8 Symbols ...
Page 14: ...Safety Instruction and Application Advice 14 Safety Instruction and Application Advice ...
Page 16: ...Unit Assembly Complying EMC 16 EMC ...
Page 18: ...General Information 18 Hardware Description CNC 0610510 12 CNC 61 00 ...
Page 24: ...Automation System CNC 61 00 24 Hardware Description CNC 0610510 12 CNC 61 00 ...
Page 31: ... Dimensions CNC 61 00 Hardware Description CNC 0610510 12 31 ...
Page 66: ...General Information Regarding the Wiring 66 Hardware Description CNC 0610510 12 ...
Page 100: ...Appendix Manufacturers 100 List of Manufacturers ...