General Information Regarding the Wiring
Hardware Description CNC 0610510/12
65
9.4
Cables for the Rotor Position Detection
Use shielded lines and shielded Submin D shells for wiring the different measuring
systems. The shield must be connected to the Submin D shell at the servo module
side and to the housing of the measuring system.
Examples for the use of conductors:
X
Motors with resolver
LIYCY 3 x 2 x 0.14 or 4 x 2 x 0.14 for motors with integrated thermal contact.
Conductors: shielded, twisted in pairs. Twist mode: sine/sine, cosine/cosine, ro-
tor/rotor and, if necessary, thermal contact/thermal contact.
For delicate applications we recommend to additionally shield the separate
pairs.
X
Motors with incremental encoder
LIYCY 5 x 0.14 or 7 x 0.14 for motors with integrated thermal contact
X
Motors with Hall effect sensor and tacho generator
LIYCY 9 x 0.14 or 12 x 0.14 for motors with integrated thermal contact.
9.5
Cables for External Ballast Resistors
The cables of the external ballast resistor of R
EX
and +UB must be twisted. If the ca-
ble is longer than 20 cm a shielded cable must be used.
Summary of Contents for CNC 0610510
Page 5: ... Content CNC 61 Hardware Description CNC 0610510 12 5 13 Appendix Revisions 101 ...
Page 6: ...Content 6 Hardware Description CNC 0610510 12 CNC 61 ...
Page 8: ...Symbols 8 Symbols ...
Page 14: ...Safety Instruction and Application Advice 14 Safety Instruction and Application Advice ...
Page 16: ...Unit Assembly Complying EMC 16 EMC ...
Page 18: ...General Information 18 Hardware Description CNC 0610510 12 CNC 61 00 ...
Page 24: ...Automation System CNC 61 00 24 Hardware Description CNC 0610510 12 CNC 61 00 ...
Page 31: ... Dimensions CNC 61 00 Hardware Description CNC 0610510 12 31 ...
Page 66: ...General Information Regarding the Wiring 66 Hardware Description CNC 0610510 12 ...
Page 100: ...Appendix Manufacturers 100 List of Manufacturers ...