Functional Description of the Connectors/Interfaces
60
Hardware Description CNC 0610510/12
CNC 61.00
8.5
Layput Plan of the Output Stage 036050001.3
X20
X30
J9
J10
Designation
Meaning
Description
X30
power supply
X20
motor phases
X31/X32
switch-over for internal/external ballast resistor
wire bridge between X31 and X32 = internal ballast resistor active
wire bridge between X31 and X32 removed = external ballast resistor active
J9/J10
Adjustment of the ballast circuirt vie the jumpers J9/J10. The jumper can be accessed from the
back side of the device.
J9 plugged = internal ballast resistor (default state when devive is delivered)
J10 plugged = external ballast resistor
F3
fuse for the logic supply, 1 A semi time-lag fuse (0360510 SC + SF); 0.63 A semi time-lag fuse
(0360510 DC + DF + EC + EF).