Functional Description of the Connectors/Interfaces
54
Hardware Description CNC 0610510/12
CNC 61.00
8.3
Error Indications
FC0
to
FC3
( Red
Flashing)
X
LED is continuously red: permanent error, e.g. emergency stop
X
LED is flashing red: error occurred and must be reset via the software
E
LED is off
F
LED flashes
D
LED is on:
LEDs
Code*
error
Reaction
Possible reason
EE
EE
0
no error
no
EE
ED
129
active monitor-
ing of travel area
reference position = actual
position
reference speed = 0
this error occurs if the limit switches of the software
are activated in the parameter file.
X
The limit switches of the software in the para-
meter file are incorrectly parameterized.
EE
DE
130
14 V not provid-
ed
reference speed = 0
and
controller OFF
1
X
possibly the option module has not been moun-
ted correctly.
EE
DD
131
-14 V not provid-
ed
reference speed = 0
and
controller OFF
1
X
possibly the option module has not been moun-
ted correctly.
ED
EE
132
short circuit
reference speed = 0
and
controller OFF
1
double peak current flows via the measuring shunt
into the output stage.
X
error when wiring the motor cables
X
a motor cable is parted or the motor cables are
pinched (especially a ground cable)
X
if the motor cables are pulled off the backpanel,
the output stage of the CNC61 is defective
ED
ED
133
reserved
no
ED
DE
134
overvoltage/
undervoltage
ref. speed = 0
and
controller
off
1,2
overvoltage:
230 V
AC
method = cutoff threshold 385 V
400 VAC method = cutoff threshold 810 V
X
the external supply of 24 V is faulty
X
the main voltage supply of the power module is
faulty (the voltage is too high)
X
the ballast resistor is not connected correctly
X
the braking power of the power module is ex-
ceeded
undervoltage:
voltage < 42 V
24 V are not provided
24 V internal:
-
overvoltage protection has responded
24 V external:
-
24 V are not provided
X
the external supply of 24 V is faulty
X
protective circuit of 24 V in the CNC61 has re-
sponded
X
the main voltage supply of the power module is
faulty (the voltage is too low)
ED
DD
135
error of first
measuring sys-
tem
reference speed = 0
and
controller OFF
1
X
a cable of the measuring system is parted or the
cables are pinched (especially a ground cable)
X
the connector of the first measuring system (X1)
is not connected or not correctly connected
X
the wiring of connector X1 at the backpanel or
of the resolver connector at the motor is faulty
DE
EE
136
motor-
Temperature
reference speed = 0
and
controller OFF
1
the motor is too hot
X
due to overload, the motor became to hot
X
PTC (NTC) is not correctly connected
X
the connection from the CNC61 to the PTC is in-
terrupted
Summary of Contents for CNC 0610510
Page 5: ... Content CNC 61 Hardware Description CNC 0610510 12 5 13 Appendix Revisions 101 ...
Page 6: ...Content 6 Hardware Description CNC 0610510 12 CNC 61 ...
Page 8: ...Symbols 8 Symbols ...
Page 14: ...Safety Instruction and Application Advice 14 Safety Instruction and Application Advice ...
Page 16: ...Unit Assembly Complying EMC 16 EMC ...
Page 18: ...General Information 18 Hardware Description CNC 0610510 12 CNC 61 00 ...
Page 24: ...Automation System CNC 61 00 24 Hardware Description CNC 0610510 12 CNC 61 00 ...
Page 31: ... Dimensions CNC 61 00 Hardware Description CNC 0610510 12 31 ...
Page 66: ...General Information Regarding the Wiring 66 Hardware Description CNC 0610510 12 ...
Page 100: ...Appendix Manufacturers 100 List of Manufacturers ...