Software (Example)
The passive transducers can be addressed with five system variables.
T_ACT [-2048..2047], T_ACT2 [-2048..2047]
The actual values of the first or second passive transducer are provided.
T_Offset [-2048..2047], T_Offset2 [-2048..2047]
These parameters define the offsets for both passive transducers. A deviation to the
zero point of the transducer can be compensated by entering the actual converter
value (T_ACTx of the unloaded transducers) into this parameter.
T_ADJ [0..15]
In order to connect different calibrating resistances to the measuring bridge (detun-
ing), values between 0 and 15 can be entered in this parameter.
Via the variable T_ADJ both passive transducers are tuned simultaneously.
1
lowest load of the bridge
15
highest detuning of the bridge
0
no detuning