Functional Description of the Connectors/Interfaces
CNC 61.00
Hardware Description CNC 0610510/12
41
8.2.2.1
Resolver Evaluation
Use a shielded cable with six leads, each 2 must be twisted. Twist mode: sine/sine,
cosine/cosine, rotor/rotor; designation of the line, e.g. LIYCY 3 × 2 × 0.14. If the ther-
mal contact is evaluated a shielded cable with 8 leads (4x2 twisted-pairs of wires)
must be used.
Pin
I/O
Function
1
O
0 V
1
2
I
S1 sine
3
0 V
1
4
I
S4 cosine
5
0 V
1
6
O
R3 rotor
7
I
thermal motor protection
2
8
0 V
1
9
I
S3 sine
10
0 V
1
11
I
S2 cosine
12
0 V
1
13
O
R1 rotor
14
0 V
1
15
O
thermal motor protection (24 V)
2
1
is connected to GND by the servo amplifier
2
If no thermal motor protection is connected, pin 15 and pin 7 must be bridged.
1
8
9
15
Summary of Contents for CNC 0610510
Page 5: ... Content CNC 61 Hardware Description CNC 0610510 12 5 13 Appendix Revisions 101 ...
Page 6: ...Content 6 Hardware Description CNC 0610510 12 CNC 61 ...
Page 8: ...Symbols 8 Symbols ...
Page 14: ...Safety Instruction and Application Advice 14 Safety Instruction and Application Advice ...
Page 16: ...Unit Assembly Complying EMC 16 EMC ...
Page 18: ...General Information 18 Hardware Description CNC 0610510 12 CNC 61 00 ...
Page 24: ...Automation System CNC 61 00 24 Hardware Description CNC 0610510 12 CNC 61 00 ...
Page 31: ... Dimensions CNC 61 00 Hardware Description CNC 0610510 12 31 ...
Page 66: ...General Information Regarding the Wiring 66 Hardware Description CNC 0610510 12 ...
Page 100: ...Appendix Manufacturers 100 List of Manufacturers ...